KHA1000 Firmware Updater

Published: January 2022 해당 기사의 공개 일자를 확인해 주세요. 제품, 가격 및 기술에 관한 정보가 최신이 아닐 수 있습니다。

VER 2.02
2024년 01월 17일

KHA1000 firmware

Resolved issues
Fixed the issue that the overall judgment was not displayed when the overall judgment became WARN when measuring with the margin set.
Resolved issues
Fixed the issue that the display color became different from normal operation due to an error in Average value judgment on the main unit result list screen when measuring with the margin set.
Resolved issues
Fixed the issue that the harmonic order judgment was not performed correctly when the margin was set and only the Average value became a warning.
Deprecated
*About the overall judgment of the previous versions. The Max value judgment functions normally, and the overall judgment will be judged normally.
VER 2.01
2023년 07월 25일

KHA1000 firmware

Resolved issues
The description of the standard for measurement techniques that conforms to JIS C61000-3-2(2019) has been revised from JIS C61000-4-7(2007) to IEC61000-4-7 Ed2.1(2009).
VER 2.00
2022년 01월 06일

KHA1000 firmware

Improvement
Complied with the following standards: IEC 61000-3-2 Ed5.0(2018), EN 61000-3-2 (2019), JIS C61000-3-2 (2019), IEC 61000-3-3 Ed3.1(2017), EN 61000-3-3 (2013)/A1(2019)
Resolved issues
Corrected the judgment of the power supply quality check function (AC power supply check function) according to the standards-Judgment of crest factor value, In IEC 61000-3-2, it has been modified from “applied to all classes” to “not applied to Class A/B”, In JIS C61000-3-2, it has been modified from “applied to all classes” to “not applied to Class A/B”